ITTGoulds PumpsPHV – Packaged Hydrovar SeriesVariable Speed Water Booster with Vertical Multistage Pump andFused DisconnectEngineered for lifeCommerci
10Goulds PumpsPHV - Packaged Hydrovar SeriesCHARACTERISTICS OF THE ELECTRIC PUMPS USED IN PHV SERIES BOOSTER PACKAGE1, 2, 3 AND 4 SSV VERTICAL MULTI-S
11HYDROVAR VERSIONSINTRODUCTIONThe HYDROVAR Concept consists mechanically of two main parts, the Power Unit and the Control Card. In its basic configur
12Goulds PumpsPHV - Packaged Hydrovar SeriesAPPLICATION EXAMPLE – MULTI-PUMP “CASCADE”MASTERINVERTERMASTERINVERTERMASTERINVERTERMASTERINVERTERRS 485CO
13OPERATION DESCRIPTIONSETS WITH VARIABLE-SPEED MOTORS AND PRESSURE TRANSDUCER CONTROLThe starting and stopping of the pumps are determined based on t
14Goulds PumpsPHV - Packaged Hydrovar SeriesSELECTING A SETThe first thing to do when selecting a package is to determine the quantity of water require
15FUSED DISCONNECT BOX: ITT Input HP / AMP Wire Tightening Fuse AMP Part Voltage Disconnect Voltage Disconnect Rating Range Torque Suppl
16Goulds PumpsPHV - Packaged Hydrovar SeriesSPECIFICATIONS Hydrovar VFD Motor HP Model * Power Supply (V) NEMA Class Install. Power Supply (V)
173500 RPM, 60 Hz HP Phase Enclosure Nameplate NEMA Goulds FLA SFA LRA S.F. Efficiency Insulation Voltage Frame PN ¹ Class
18Goulds PumpsPHV - Packaged Hydrovar SeriesPERFORMANCE WITH VARYING SPEED FOR CENTRIFUGAL PUMPSFitting the electric pump with a variable speed drive
19VARIABLE SPEED PERFORMANCE CURVES1SV VARIABLE SPEED CURVESSVB 304SS Multi-Stage Pumps MODEL: 1SVB 6 StageHydraulic Data Maximum Flow Flow at Dut
2Goulds PumpsPHV - Packaged Hydrovar SeriesCONTENTSSelection Chart …………………………………………………………………………………………… 3Main Components ……………………………………………………………………………
20Goulds PumpsPHV - Packaged Hydrovar SeriesVARIABLE SPEED PERFORMANCE CURVES1SV VARIABLE SPEED CURVESSVB 304SS Multi-Stage Pumps MODEL: 1SVB 9 Stag
21VARIABLE SPEED PERFORMANCE CURVES1SV VARIABLE SPEED CURVESSVB 304SS Multi-Stage Pumps MODEL: 1SVB 15 StageHydraulic Data Maximum Flow Flow at Du
22Goulds PumpsPHV - Packaged Hydrovar SeriesVARIABLE SPEED PERFORMANCE CURVES2SV VARIABLE SPEED CURVESSVB 304SS Multi-Stage Pumps MODEL: 2SVB 5 Stag
23VARIABLE SPEED PERFORMANCE CURVES2SV VARIABLE SPEED CURVESSVB 304SS Multi-Stage Pumps MODEL: 2SVB 8 StageHydraulic Data Maximum Flow Flow at Dut
24Goulds PumpsPHV - Packaged Hydrovar SeriesVARIABLE SPEED PERFORMANCE CURVES2SV VARIABLE SPEED CURVESSVB 304SS Multi-Stage Pumps MODEL: 2SVB 13 Sta
25VARIABLE SPEED PERFORMANCE CURVES3SV VARIABLE SPEED CURVESSVB 304SS Multi-Stage Pumps MODEL: 3SVB 7 StageHydraulic Data Maximum Flow Flow at Dut
26Goulds PumpsPHV - Packaged Hydrovar SeriesVARIABLE SPEED PERFORMANCE CURVES3SV VARIABLE SPEED CURVESSVB 304SS Multi-Stage Pumps MODEL: 3SVB 9 Stag
27VARIABLE SPEED PERFORMANCE CURVES3SV VARIABLE SPEED CURVESSVB 304SS Multi-Stage Pumps MODEL: 3SVB 13 StageHydraulic Data Maximum Flow Flow at Du
28Goulds PumpsPHV - Packaged Hydrovar SeriesVARIABLE SPEED PERFORMANCE CURVES4SV VARIABLE SPEED CURVESSVB 304SS Multi-Stage Pumps MODEL: 4SVB 2 Stag
29VARIABLE SPEED PERFORMANCE CURVES4SV VARIABLE SPEED CURVESSVB 304SS Multi-Stage Pumps MODEL: 4SVB 4 StageHydraulic Data Maximum Flow Flow at Dut
3PHV SERIES SELECTION CHART (PACKAGED HYDROVAR)HYDRAULIC PERFORMANCE RANGE AT 60 Hz SSV FLOW Pump Stage HP 0 GPM 5 7.5 10 12.5 15 17.5
30Goulds PumpsPHV - Packaged Hydrovar SeriesVARIABLE SPEED PERFORMANCE CURVES4SV VARIABLE SPEED CURVESSVB 304SS Multi-Stage Pumps MODEL: 4SVB 7 Stag
31VARIABLE SPEED PERFORMANCE CURVES33SV VARIABLE SPEED CURVESVB CI/316SS Multi-Stage Pumps MODEL: 33SVB 1/1 StageHydraulic Data Maximum Flow Flow
32Goulds PumpsPHV - Packaged Hydrovar SeriesVARIABLE SPEED PERFORMANCE CURVES33SV VARIABLE SPEED CURVESVB CI/316SS Multi-Stage Pumps MODEL: 33SVB 1
33VARIABLE SPEED PERFORMANCE CURVES33SV VARIABLE SPEED CURVESVB CI/316SS Multi-Stage Pumps MODEL: 33SVB 2/1 StageHydraulic Data Maximum Flow Flow
34Goulds PumpsPHV - Packaged Hydrovar SeriesVARIABLE SPEED PERFORMANCE CURVES33SV VARIABLE SPEED CURVESVB CI/316SS Multi-Stage Pumps MODEL: 33SVB 3/
35VARIABLE SPEED PERFORMANCE CURVES46SV VARIABLE SPEED CURVESVB CI/316SS Multi-Stage Pumps MODEL: 46SVB 1/1 StageHydraulic Data Maximum Flow Flow
36Goulds PumpsPHV - Packaged Hydrovar SeriesVARIABLE SPEED PERFORMANCE CURVES46SV VARIABLE SPEED CURVESVB CI/316SS Multi-Stage Pumps MODEL: 46SVB 1
37TECHNICAL DATA – PUMP HYDRAULICS / MOTOR SIZING1SV 3500 RPM Number of Maximum Motor HP for use Motor HP for use Shutoff Shutoff Stages HP
38Goulds PumpsPHV - Packaged Hydrovar Series33SV 3500 RPM # of Impellers / Maximum Motor HP for use Motor HP for use Shutoff Shutoff Casing / Sl
39TECHNICAL DATA – PUMP HYDRAULICS / MOTOR SIZING46SV 3500 RPM # of Impellers / Maximum Motor HP for use Motor HP for use Shutoff Shutoff Casing
4Goulds PumpsPHV - Packaged Hydrovar SeriesMAIN COMPONENTSof PHV Series constant pressure variable speed system• One multistage vertical pump, Goulds
40Goulds PumpsPHV - Packaged Hydrovar SeriesTECHNICAL DATA Pump Number of Stages Maximum Inlet Pressure 1SV 2-16 Stages 145 psi (10 bar) 17-22
41PHV — PACKAGED HYDROVAR SERIES — 1SVB Frame L2 DI Weights (lb.) Stage (3-Phase) HP L1 (max.) TEFC TEFC
42Goulds PumpsPHV - Packaged Hydrovar SeriesPHV — PACKAGED HYDROVAR SERIES — 2SVB Frame L2 DI Weights (lb.) Stage (3-Phase) HP L1
43 Frame L2 DI Weights (lb.) Stage (3-Phase) HP L1 (max.) TEFC TEFC L6 L7 L8 MI TEFC Liquid TEFC H
44Goulds PumpsPHV - Packaged Hydrovar Series Frame L2 DI Weights (lb.) Stage (3-Phase) HP L1 (max.) TEFC
45 Frame L2 DI Weights (lb.) Stage (3-Phase) HP L1 (max.) TEFC TEFC L6 L7 L8 MI TEFC Liquid TEFC H
46Goulds PumpsPHV - Packaged Hydrovar Series Frame L2 DI Weights (lb.) Stage (3-Phase) HP L1 (max.) TEFC
47NPSHThe minimum operating values that can be reached at the pump suction end are limited by the onset of cavitation.Cavitation is the formation of v
48Goulds PumpsPHV - Packaged Hydrovar SeriesTECHNICAL DATA – WATER PROPERTY CHART Temp ºF Temp ºC Specific Volume Specific Gravity Weight Vapor
49VOLUMETRIC CAPACITY Litres Cubic metres Cubic feet Cubic feet Imp. gal. US gal. per minute per hour per hour per minute per minute per m
5PART NUMBERING / IDENTIFICATION CODES — PHV SERIESOption List in order shown:P = Premium Efficiency F = Harmonic Filter T = 500 PSI TransducerReduce
50Goulds PumpsPHV - Packaged Hydrovar SeriesNOTES
51NOTES
ITT 2881 East Bayard Street, Seneca Falls, NY 13148 Phone: (315) 568-7123 • Fax: (315) 568-7973www.goulds.comGoulds Pumps and G&L are registered t
6Goulds PumpsPHV - Packaged Hydrovar SeriesPHV SeriesSPECIFICATIONS• Flow rate up to 320 GPM.• Head up to 692’ TDH.• Supply voltage:1Ø, 230V ± 10% up
7MARKETS AND APPLICATIONS (continued)WATER SUPPLY AND PRESSURE BOOSTING• Pressure boosting in buildings, hotels, residential complexes• Pressure bo
8Goulds PumpsPHV - Packaged Hydrovar SeriesMARKETS AND APPLICATIONS (continued)MUNICIPAL, AGRICULTURAL, LIGHT INDUSTRY, WATER TREATMENT, HEATING AND
9MAIN CHARACTERISTICS OF FREQUENCY CONVERTERS USED IN THE PHV BOOSTER SETSThe PHV series booster sets use a Hydrovar® variable frequency drive, an aut